RNG Fueling Stations are designed to compress upgraded renewable natural gas (RNG) into high-pressure fuel for vehicle refueling. They are suitable for renewable energy project developers, biogas plant operators, natural gas suppliers, CNG station investors, EPC contractors, gas equipment distributors and commercial fleet operators looking to develop or expand renewable gas fueling infrastructure.
Technical Specifications
The system uses hydraulic reciprocating compression technology, with configurations available for different gas flow and pressure requirements.
|
Parameter |
Specification |
|
Model Series |
TYCZ-RNG / ZXRY1000-II |
|
Compressed Medium |
Renewable Natural Gas (RNG/Bio-CNG) |
|
Average Flow Rate |
1,200–2,500 Nm³/h |
|
Inlet Pressure |
3–20 MPa |
|
Maximum Outlet Pressure |
≤25 MPa |
|
Compression Type |
Two-stage hydraulic reciprocating |
|
Drive System |
Motor-driven hydraulic pump |
|
Gas Chamber Lubrication |
Oil-free |
|
Main Motor Configuration |
2 × 45 kW / Optional 2 × 110 kW |
|
Cooling System |
Closed-loop cooling with air-cooled radiator |
|
Control System |
PLC and HMI |
|
Operating Temperature |
-40°C to +55°C |
|
Skid Dimensions |
4,350 × 2,300 × 2,650 mm |
Different configurations are available according to project throughput, inlet conditions and operating requirements. Final motor power and system energy consumption depend on the selected compressor model.
Gas Quality Protection
RNG compression requires attention to gas purity and contamination control. The compressor uses a multi-stage sealing structure to separate the gas chamber from the hydraulic oil chamber, reducing the risk of oil entering the compressed gas stream.
Available protection and monitoring configurations include:
• Oil-free gas chamber design with multi-stage sealing.
• Gas inlet filtration for particulate and moisture control.
• Hydraulic oil filtration and monitoring.
• Gas pressure and temperature monitoring.
• Optional gas composition monitoring interface.
Incoming RNG must be upgraded and purified to meet the compressor's specified gas quality requirements before compression.
System Configuration and Safety Control
RNG Fueling Stations can be supplied as compressor skids or integrated with downstream storage and dispensing equipment.
|
System |
Available Configuration |
|
Gas Storage |
ZIP-270 high-pressure storage cylinders |
|
Dispensing |
CNG dispensers with dual-hose options |
|
Gas Metering |
E+H mass flow meter options |
|
Gas Unloading |
Tube trailer unloading equipment |
|
Automation |
Siemens PLC and HMI options |
|
Communication |
MODBUS RTU/RS485, TCP/IP |
Safety configurations include combustible gas detection, pressure and temperature alarms, emergency shutdown interfaces and hydraulic overpressure protection. Explosion-proof equipment can be selected according to site classification and applicable market requirements.
Manufacturing and Project Support
Qingdao Lenado Intelligent Equipment Co., Ltd. provides gas compression equipment manufacturing and project configuration services, supported by CNC machining and an ISO 9001-certified quality management system.
Project support covers:
• Compressor selection based on gas flow and pressure requirements.
• Skid-mounted and containerized equipment configuration.
• Electrical control and safety system integration.
• Installation and commissioning assistance.
• Operator training, spare parts and maintenance support.
A 12-month warranty is available according to the applicable company warranty terms.
FAQ
Q: Can RNG Fueling Stations process untreated biogas?
A: No. Raw biogas from landfills, wastewater treatment plants or agricultural digesters requires gas upgrading and purification before entering the compression system.
Q: What information is needed for compressor selection?
A: The main requirements are gas composition, inlet pressure, required flow rate, discharge pressure and daily operating hours. These details help determine compressor capacity and system configuration.
Q: What maintenance is required?
A: Routine maintenance includes inspection of gas inlet filters, hydraulic oil filters, sealing elements and cooling components. Maintenance intervals depend on operating hours and gas quality.
Q: Can the system meet different international certification requirements?
A: Explosion protection, electrical equipment and pressure vessel documentation can be configured according to destination-market requirements. Applicable CE, ATEX and PED documentation should be confirmed for the selected equipment.
Hot Tags: rng fueling stations, China rng fueling stations manufacturers, factory, CNG Station Compressor, Complete CNG Dispensing Station, Complete CNG Fill Up Stations, Natural Gas Charging Stations, Open CNG Gas Station, Rng Fueling Stations