The Complete CNG Auto Filling Station integrates natural gas treatment, dehydration, compression, high-pressure storage, sequential control, and vehicle dispensing into a coordinated refueling system. Designed for bus depots, logistics fleets, and commercial CNG stations, it provides integrated equipment configurations for projects requiring reliable, high-volume vehicle refueling.
CNG Station Models and Capacity
Two configurations are available to accommodate different station throughput requirements.
|
Technical Parameters |
Standard Model |
Heavy-Duty Model |
|
Model |
TYCZ-S-1600 |
TYCZ-S-2400 |
|
Gas Flow Rate |
1,600 Nm³/h |
2,400 Nm³/h |
|
Compression Stages |
3 |
4 |
|
Motor Power |
132 kW × 2 |
160 kW × 2 |
The TYCZ-S-1600 is suitable for medium-scale refueling operations, while the TYCZ-S-2400 provides higher rated gas flow for larger demand. Station selection should account for inlet gas pressure, required discharge pressure, daily gas consumption, storage capacity, and vehicle refueling schedules.
Actual operating output depends on gas supply conditions and the selected system configuration.
Integrated CNG Processing and Refueling Equipment
The complete station combines the following equipment into a coordinated gas processing and dispensing system:
• Gas Reception and Purification: Receives incoming natural gas and removes impurities before compression.
• Deep Dehydration Unit: Uses a dual-tower molecular sieve system with automatic regeneration to achieve a specified dew point of -60°C.
• CNG Compression Unit: Uses hydraulic-driven reciprocating compressors to increase gas pressure for storage and vehicle refueling.
• High-Pressure Storage System: Stores compressed natural gas and supplies gas to the station distribution system.
• Priority Control System: Coordinates gas distribution between storage banks and dispensing lines.
• CNG Dispensers: Deliver compressed natural gas to vehicles through the configured refueling lines.
Equipment combinations and supply scope can be configured according to project requirements and existing site infrastructure.
Three-Line Refueling Configuration
The three-line refueling arrangement supports simultaneous gas dispensing to multiple vehicles, making it suitable for bus depots, logistics centers, and other fleet operations with concentrated refueling demand.
By coordinating gas distribution across three refueling lines, the configuration helps manage vehicle queues and accommodate scheduled fleet refueling. Its effectiveness depends on compressor output, high-pressure storage capacity, priority control settings, and dispenser configuration.
Compressor, Control and Safety Systems
The compression system uses hydraulic-driven reciprocating compressor technology, PLC-based control, and variable frequency drive (VFD) operation. Dual compressor arrangements can be configured to support operating flexibility and maintenance requirements.
The station can incorporate the following safety and monitoring equipment:
• Emergency Shutdown System (ESD): Provides emergency shutdown functions.
• Combustible Gas Leakage Detection: Monitors gas leakage in designated areas.
• Overpressure Protection: Protects pressure-bearing equipment against excessive operating pressure.
• Explosion-Proof Electrical Components: Supports electrical safety in designated hazardous areas.
• Flame Detection: Available as an optional fire-monitoring feature.
Control logic, protective devices, and electrical configurations are determined by the station design, installation environment, and applicable local regulations.
Manufacturing and System Integration
Our natural gas equipment manufacturing experience includes hydraulic reciprocating compressors for CNG daughter stations, standard filling stations, and mother stations.
This compressor manufacturing background supports the selection and integration of core compression equipment within complete CNG station configurations. The station system brings together gas purification, dehydration, compression, high-pressure storage, priority control, and dispensing equipment according to project requirements.
Equipment configuration, technical documentation, and system interfaces are coordinated to support project installation and commissioning.
Technical Support
We provide technical assistance for equipment operation and routine maintenance throughout station operation.
Operating Documentation: Equipment operation manuals, maintenance instructions, and technical documents.
Control System Assistance: Guidance on PLC operation, alarm identification, and basic troubleshooting.
Maintenance Guidance: Routine inspection, lubrication, and compressor maintenance procedures.
Fault Diagnosis: Technical assistance in identifying equipment faults and analyzing abnormal operating conditions.
Spare Parts Support: Replacement parts for compressor maintenance and equipment servicing.
FAQ
Q: What factors affect the actual gas output of a CNG filling station?
A: Actual output depends on inlet gas pressure, required discharge pressure, compressor operating conditions, gas supply stability, and the coordination of storage and dispensing equipment. Rated compressor flow should therefore be evaluated alongside the complete station configuration.
Q: Can a complete CNG station be integrated with existing equipment?
A: Yes. Integration requirements depend on the specifications and condition of existing compressors, storage vessels, gas pipelines, control systems, and dispensers. Equipment interfaces and system compatibility need to be evaluated during project design.
Q: What information is needed to determine the station installation requirements?
A: Site layout, available installation space, electrical supply, gas pipeline connections, ventilation conditions, hazardous-area classification, and local safety regulations are important considerations when planning station installation.
Hot Tags: complete CNG auto filling station, China complete CNG auto filling station manufacturers, factory, CNG Station Compressor, Complete CNG Auto Filling Station, Complete CNG Dispensing Station, Complete CNG Filling Station Compressor, Mobile CNG Refueling Station, Rng Fueling Stations